公称通径DN (mm) | 流量范围 (m3/h) | ||
液体 | 气体 | 蒸汽 | |
15 | 0.4-4 | 4-30 | 3.2-18 |
20 | 0.7-7 | 6-40 | 5-32 |
25 | 1-10 | 11-70 | 9-60 |
32 | 1.5-15 | 17-150 | 15-130 |
40 | 2-25 | 24-240 | 20-200 |
50 | 3-45 | 37-370 | 32-320 |
65 | 5.5-75 | 65-650 | 55-540 |
80 | 8.5-110 | 95-950 | 81-810 |
100 | 16-180 | 150-1500 | 130-1300 |
125 | 25-270 | 245-2400 | 200-2000 |
150 | 35-350 | 360-3600 | 290-2900 |
200 | 60-600 | 600-6000 | 550-5000 |
250 | 90-900 | 900-9000 | 800-8000 |
300 | 135-1350 | 1350-13500 | 1150-11500 |
350 | 185-1850 | 1850-18500 | 1550-15500 |
400 | 240-2400 | 2400-24000 | 2100-21000 |
450 | 300-3000 | 3000-30000 | 2600-26000 |
500 | 380-3800 | 3800-38000 | 3300-33000 |
600 | 550-5500 | 5500-55000 | 5100-51000 |
700 | 750-7500 | 7500-75000 | 7000-70000 |
800 | 950-9500 | 9500-95000 | 9000-90000 |
900 | 1200-12000 | 12000-137000 | 11000-110000 |
1000 | 1400-1400 | 14000-140000 | 13500-135000 |
1200 | 2000-20000 | 20000-200000 | 19500-195000 |
1300 | 2200-22000 | 22000-220000 | 21000-210000 |
1400 | 2750-27500 | 27500-275000 | 27000-270000 |
1500 | 3150-31500 | 31500-315000 | 31000-310000 |
涡街流量计安装注意事项
仪表的正确安装是保障仪表正常运行的重要环节,若安装不当,轻则影响仪表的使用精度,重则会影响仪表的使用寿命,甚至会损坏仪表。
安装环境要求
1、尽可能避开强电、强磁、高频、强开关电源等设备,仪表的供电电源尽可能与这些设备分离。2、避开高温热源和辐射源的直接影响。若必须安装,须有隔热通风措施。
3、避开高湿环境和强腐蚀气体环境。若必须安装,须有通风措施。
4、仪表安装在室内,安装在室外应注意防水,特别注意要将仪表表头用于穿线的防水接头拧紧,并将电缆线弯成U形,避免水顺着电缆线进入仪表表头内。
5、仪表安装点周围应该留有较充裕的空间,以便安装接线和定期维护。
安装点的选择
1、仪表在管道上可以正装、侧装或倒装,但一般不建议倒装;
2、流量计安装点的上下游必须有一定的直管道以稳定流体的流场,直管段Z低要求如下图一(D:管道内径mm ) ,特别注意当前面为泵、空压机或调节阀时,流量计安装点应尽可能的远离它们;
3、安装点应无振动干扰,若有振动应对安装管道和流量计安装点上下游2D处加设管道紧固装置或支撑来减小或消除振动;
4、安装点应选择在一些储气罐、分汽包之后,如有阀门一般安装在流量计下游;
5、测量气体时,在垂直管道安装仪表,气体流向不限。但若管道内含少量液体,为了防止液体进入仪表测量管,气流应不下而上流动,如图a所示;
6、测量液体时,为保证管内充满液体,在垂直或倾斜管道安装仪表时,应该保证液体流动方向从下而上。若管内含少量气体,为了防止气体进入仪表测量管,仪表应安装在管线的较低处(如图b所示) ;
7、如安装条件允许,或需断流检查与清洗传感器,应设置旁通管道;
8、测压孔和测温孔的安装设计。被测管道需要安装温度和压力变送器时,测压孔应设置在下游3-5D处,测温孔应设置在下游6-8D处,D为仪表公称口径,单位:mm。